# CRY SOUND 2620: how manufacturers use it

> 1 sourced use case in the AI Agents for Manufacturing library where a manufacturer deployed CRY SOUND 2620, with the reported result, evidence level and sources. Not a ranking or an endorsement.

- Canonical URL: https://aiagentsformanufacturing.com/tools/cry-sound-2620/
- Use cases: 1
- Last updated: 2026-11-12
- Publisher: AI Agents for Manufacturing (https://aiagentsformanufacturing.com)
- Evidence levels explained: https://aiagentsformanufacturing.com/evidence/
- All AI tools: https://aiagentsformanufacturing.com/tools.md
- All cases: https://aiagentsformanufacturing.com/llms.txt

Figures are as reported by each case's sources (often the vendor) and are not independently verified; each case page says who reports them.

## [Acoustic cameras find and size compressed air leaks while the line runs, so maintenance fixes the costly ones first (Schneider Electric, Altex/Toyota Industries)](https://aiagentsformanufacturing.com/use-cases/acoustic-camera-compressed-air-leak-detection-sizing-schneider-electric-altex/)

- Markdown: https://aiagentsformanufacturing.com/use-cases/acoustic-camera-compressed-air-leak-detection-sizing-schneider-electric-altex.md
- Evidence level: Verified
- Department: Maintenance
- Tools line: CRY SOUND 2620 acoustic camera: used at Altex (Toyota Industries group)
- Manufacturers named: Schneider Electric (https://aiagentsformanufacturing.com/companies/schneider-electric.md), Altex (https://aiagentsformanufacturing.com/companies/altex.md)
- Added: 2026-11-12

Schneider Electric (US Department of Energy Better Plants implementation model): 40 staff trained on acoustic imagers; more than 250 leaks identified across six facilities, over $60,000 in annual savings and more than 300 metric tons of CO2 avoided per year once repaired; the company plans to use the same tools for gas, steam and vacuum leaks, pump cavitation, noisy bearings and electrical discharge. Altex, Toyota Industries group (article by the camera distributor AirMore): many previously unknown small leaks found in the first TPM activity, 5 to 6 repaired, inspection time much shorter, some machine faults traced to pressure drops caused by leaks; estimated annual savings of about 3 million yen. Unnamed automotive parts manufacturer (FLIR case study, four-week trial): 68 leaks found; fixing only 15 of them cut compressed air use by 54.6 m3 per hour (15%), 230.4 kg of CO2 per day and more than $4,000 a year in electricity.

Sources:
- https://betterbuildingssolutioncenter.energy.gov/implementation-models/schneider-electric-using-state-art-acoustical-imaging-technology-compressed
- https://n-airmore.com/en/column/interview3
- https://www.flir.com/discover/industrial/case-study-tackling-compressed-air-leaks-in-automotive-parts-manufacturing-with-acoustic-imaging/

---
Please cite the canonical URL: https://aiagentsformanufacturing.com/tools/cry-sound-2620/